Categories: FDA

Two draft guidances issued together late last month seek to increase both clinical trial efficiency and the amount of information that is available about a drug’s safety and benefits.  The two draft guidances address, respectively, adaptive designs and master protocols.  This blog post discusses FDA’s recommendations for adaptive designs; master protocols will be addressed in a subsequent blog post.

An adaptive design is a “clinical trial design that allows for prospectively planned modifications to one or more aspects of the design based on the accumulating data from subjects in the trial.”  The ability to make changes to a study in progress allows investigators to take into account new information that was not known when the study began.  According to FDA, adaptive designs can both provide a greater chance to detect a true drug effect and reduce the number of patients exposed to ineffective investigational treatments (since effectiveness will be more easily detected earlier in the trial).  Because adaptive designs allow for greater flexibility, they also may be more acceptable to those conducting and those participating in clinical trials. For sponsors in particular, adaptive designs can potentially both save time and reduce costs.  Adaptive design can also have ethical advantages by facilitating early termination of trials once it becomes clear that a trial is unlikely to demonstrate effectiveness, thereby minimizing risk to participants.

At the same time, the draft guidance recognizes that adaptive designs increase the risk of “Type I” (false positive) errors, i.e., concluding that a drug has a beneficial effect when it does not.  To mitigate this risk, the draft guidance recommends sponsors employ methods to determine appropriate statistical thresholds for interim and final analysis to ensure that the overall Type I error is controlled at 2.5 percent.  Similarly, the draft guidance acknowledges the risk of bias that can result from early unblinding of a study, and recommends limitations on who may access such data to mitigate this risk.

A key element of adaptive design is pre-specification (i.e., planning in advance), including pre-specification of the number and timing of interim analyses, what statistical methods will be used to interpret the interim data, and how the study design will be changed depending on the results of such analyses.  Failure to pre-specify can result in the introduction of bias and thereby put the quality and integrity of study data at risk. Therefore, FDA strongly recommends that prespecified protocols are included in the clinical study design to ensure that access to comparative interim results are limited to individuals with relevant expertise who are independent from personnel involved in conducting or managing the trial.

Because adaptive designs introduce certain added complexities, FDA recommends that sponsors provide additional information when submitting a protocol for FDA review, including a detailed description of the monitoring and adaptation plan, information on who will be responsible for implementing the adaptive design, pre-specification of the statistical methods to be used, and a comprehensive written data access plan to maintain data integrity and quality.

The new adaptive designs draft guidance supersedes an earlier draft guidance issued in 2010.  At that time, adaptive designs were in their infancy, and proponents of adaptive designs viewed FDA’s initial guidance as a first step in considering how best to integrate them into clinical trials to support FDA regulated products and recommended that FDA guidance evolve in response to greater experience with the use of different adaptive study designs.  The new draft guidance reflects such evolution in FDA’s thinking; for example, in acknowledging the potential adverse impact arising from Type I error and in eliminating confusing categorization of “well understood” and “not well understood” adaptive design methods in favor of a more focused assessment of factors, such as unblinding, that can increase risk of bias.

FDA encourages sponsors to consider and discuss prospective design options with FDA.  Clinical trial sponsors and other stakeholders may want to consider the potential impact of the new guidance on their approach to clinical trials, and to submit comments to the FDA.  The deadline for submitting comments is November 30, 2018.

Back to Health Law Advisor Blog

Search This Blog

Blog Editors

Related Services

Topics

Archives

Jump to Page

Subscribe

Sign up to receive an email notification when new Health Law Advisor posts are published:

Privacy Preference Center

When you visit any website, it may store or retrieve information on your browser, mostly in the form of cookies. This information might be about you, your preferences or your device and is mostly used to make the site work as you expect it to. The information does not usually directly identify you, but it can give you a more personalized web experience. Because we respect your right to privacy, you can choose not to allow some types of cookies. Click on the different category headings to find out more and change our default settings. However, blocking some types of cookies may impact your experience of the site and the services we are able to offer.

Strictly Necessary Cookies

These cookies are necessary for the website to function and cannot be switched off in our systems. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. You can set your browser to block or alert you about these cookies, but some parts of the site will not then work. These cookies do not store any personally identifiable information.

Performance Cookies

These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. All information these cookies collect is aggregated and therefore anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.